Name | Ifp Clamp |
Lead Time | 0-3 days |
Specialty | Obstetrics & Gynecology-Forceps – Hysterectomy |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | seemab surgical |
Sterility | Non-Sterile |
Usage | Reusable |
Clamp
infundibular pelvic clamp, s-curved ?Infundibular Pelvic Clamp is designed to reach high-up structures in the pelvis during vaginal hysterectomy salpingo-oopherectomy procedures. The s-shaped shanks provide optimal contouring ability and are the ideal shape for deep pelvic procedures.
Description
Shipping & Delivery
Related products
Hern Kelly Forceps
Blumenthal Ovum Forceps
slightly curved, concave tip, 20.0 mm jaw, coarse teeth, 13" (33.0 cm) Blumenthal Ovum Forceps are ideal in the removal of placental tissue or other products of conception from the uterus to prevent infections. The hollow blades are slightly curved with coarse teeth on the jaws to firmly grasp the tissue to be removed. The concave tip is designed to prevent grasping the fundus of the uterus.
Bierer Tenaculum
angled jaws, 5x6 teeth, 9" (22.9 cm) ?Bierer Tenaculum is commonly used in gynecology to stabilize a woman's cervix or uterus during a procedure. The tenaculum features angled jaws and inward facing hooks with 5X6 teeth to firmly grasp the tissue. The ring handles have a lock mechanism to hold the blades in various positions.
Duplay Tenaculum Forceps
Faure Peritoneal Clamp Forceps
slight curve, 8-1/4" (21.0 cm)?Faure Peritoneal Clamp Forceps are commonly used to remove the peritoneum tissue from the pelvic cavity for gynecological procedures. The ring handles feature a locking mechanism to hold the forceps in position. The slightly curved serrated blades keep a firm grip on the peritoneal tissue during the procedure.
Boston Ovum Forceps
Bill Traction Handle
for use w/ all standard handle type o.b. forceps?Bill Traction Handle is designed to increase the accuracy of traction to the path of least resistance. The handle features a claw that is applied to the finger guards of standard obstetrical forceps. The claw is then attached via a vertical rod and movable joint to a handle grip that is held by the obstetrician.
Heaney Hysterectomy Forceps
Heaney Hysterectomy Forceps are commonly used during the hysterectomy procedure to clamp off a tough ligament on both sides of the uterus. The forceps feature ring handles with a lock mechanism and serrated blades to firmly grasp the ligament. Available straight or curved with single or double grooves on the blades in various lengths to accommodate a wide range of cases.